Characteristic quantities
Designation: 80A solenoid plunger relay
Rated voltage: 6V; 12V; 24V (1)
Design; Closed
Mode of operation: Continuous operation up to 1h
Voltage limits (permissible): 0,75 x rated voltage; after 1h continuous operation up to rated voltage
Switching times at rated voltage: Response time ? 50 ms; Release time ? 30 ms
Useage category: Starting, switch off during operation DC4-VDE 0660
Creepage distances and air gaps: based on insulation group C-VDE 0110
Coil power: 13 W
Coil connection: Terminal screws, for conductor diameter 3 mm
Main current contacts: Make contact, break contact
Contact material: Copper
Stud: M8; Permissible tightening torque 10...15 Nm
Degree of protection (refer to Page 5): Terminals IP 00; Housing IP 54
Operating-temperature range: - 40 ...+ 100 °C
Note: For continuous operation, ensure adequate ventilation (cooling).
(1) Excitation and switching voltage
|